Can my panel handle it?

The most common expensive surprise in sauna ownership: the heater needs a dedicated 240V circuit your house doesn't have room for. Check before you order — not after the crate arrives.

The three questions to settle before ordering

1. Is there physical space in the panel? A 240V circuit takes a double-pole breaker — two adjacent slots. Full panel ≠ no options (quad breakers exist), but it adds cost.
2. Is there capacity? Only a licensed electrician's NEC load calculation answers this definitively — our verdict above is a screening estimate, not a substitute.
3. How far is the run? Distance and trenching (for outdoor saunas) often cost more than the circuit itself. Get the quote with the run measured, not over the phone.

This tool provides educational estimates using standard formulas (amps = watts ÷ volts; breakers sized at 125% of continuous load per NEC 210.19/20). It is not electrical advice, and SaunaClear is not an electrician. Always hire a licensed electrician for sizing and installation. Estimating your total project? Feed the electrical figure into the True-Cost Calculator.